Panasonic PTD9610E Provozní pokyny

Procházejte online nebo si stáhněte Provozní pokyny pro Datové projektory Panasonic PTD9610E. Panasonic PTD9610E Operating Instructions Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 94
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
PROJECTOR
P
O
W
E
R
S
Y
S
T
E
M
S
E
L
E
C
T
O
R
S
T
D
R
G
B
I
N
P
U
T
1
I
N
P
U
T
2
I
N
P
U
T
3
BRIGHT
CONTRAST
LENS
+
P
C
-
M
U
T
E
O
N
S
C
R
E
E
N
N
E
X
T
ID SELECT
I
D
A
L
L
1
2
3
4
5
6
7
8
9
0
M
E
N
U
E
N
T
E
R
Read these instructions completely before operating this unit.
TQBJ0085
Operating Instructions
1-94
Bedienungsanleitung
95-187
DLP™ based Projector Commercial Use
Models No. PT-D9510E
PT-D9610E
Operating Instructions
Zobrazit stránku 0
1 2 3 4 5 6 ... 93 94

Shrnutí obsahu

Strany 1 - PT-D9610E

PROJECTORPOWERSYSTEMSELECTORSTDRGBINPUT1INPUT2INPUT3BRIGHTCONTRASTLENS–+PC-MUTEONSCREENNEXTID SELECTID ALL1234567890MENUENTERRead these instructions c

Strany 2 - Contents

ENGLISHName and function of each part〈Projector〉POWER buttonThis button is used to turn the projectorpower supply on and off.•This button is enabled w

Strany 3 - Features

11ENGLISHName and function of each remote control part〈Remote control unit〉STD (standard) buttonThis button is used to reset all of the projector adju

Strany 4

12ENGLISHName and function of each remote control part (continued)〈Remote control unit〉TransmitterThis emits the infrared signals which areused to con

Strany 5 - IMPORTANT SAFETY NOTICE

Before using the remote control unitInserting the batteries• Insert the AA batteries supplied with the remote control unit, making sure that the polar

Strany 6 - Setting-up

ENGLISH14PROJECTORBRIGHTCONTRASTPOWERINPUT 1INPUT 2STDRGBLENS1234567809NEXTPIC MUTE ID-SELECTON SCREENID-ALL>PS<SYSTERSELECTORIN

Strany 7 - When using the projector

ENGLISHTurning the power ON and OFFAlways be sure to follow the procedure given below to turn the projector power on and off.〈Turning the power on〉〈Tu

Strany 8 - Precautions on handling

16The figure below shows on-screen displays for any desired setting, starting with the MAIN MENU, and ending withits sub-menu.Normal screenLENSLENS FO

Strany 9 - Notes on use

17ENGLISHThe projection lenses and input modules which are available for use with this projector need to be purchasedseparately , and must be installe

Strany 10 - Projector

ENGLISH18Setting up the projectorInstalling to the floor (Including the direct rear-mounting)1. Installing drawing of the screen and the projector (un

Strany 11 - Remote control unit

ENGLISHInstalling to the ceiling (Including direct rear-projection)19• Using the projector by installing to the ceiling requires an optional ceiling m

Strany 12

ENGLISHDear Panasonic Customer:This instruction booklet provides all the necessary operating information that you might require. We hope it willhelp y

Strany 13 - Operating range of remote

ENGLISH20Projection distance for each projection lens(sold separately)LSHScreenThe required projection distance depends on not only the target picture

Strany 14 - Using REMOTE IN 1 Terminal

ENGLISH21NOTE:• The projection distance listed in the table may have a variation within ± 5 %.• Keystone (trapezoidal distortion) is compensated to be

Strany 15 - Turning the power ON and OFF

22ENGLISHProjection distance measurements for PT-D9610E(screen aspect ratio: 16:9)unit: mm (feet/inches)NOTE:• The projection distance listed in the t

Strany 16 - SELECT :

23Calculation of the projection distance for each projection lens (for PT-D9510E)If there is no reference made to the require picture size, calculate

Strany 17 - Before using the projector

24ENGLISHAdjusting projector feet[ Side view ][ Front view ]Adjustable feetThe four feet on the bottom of the projector are adjustable for the height

Strany 18 - Setting up the projector

25ENGLISHSetting the projection methodThe projection method can be set in accordance with the way the projector has been installed. If the projectedpi

Strany 19 - [Bottom view]

26ENGLISHAdjusting the lensAdjusting the focusAdjustment procedurePress the LENS button. ... The LENS screen will be displayed.Use the control level b

Strany 20 - (sold separately)

27ENGLISHAdjustment range after lens positioning is as follows:※The numbers in brackets are the dimensions when the ET-D95LE9 lens is being used.Adjus

Strany 21 - ET-D95LE9

28ENGLISHObtain the required input modules (sold separately) beforehand in accordance with the system input signal.• Types of input module (sold separ

Strany 22

29ENGLISHDisconnect the power supply from the projector before installing any of the input modules.Installation procedureRemove the two screws which a

Strany 23 - Zoom lens

3ENGLISHProduct OutlineThis is a high-luminance DLPTMbased projector which is powered by a single-phase, 3-wire type 200 V–240 Vpower supply. It utili

Strany 24 - Adjusting projector feet

30ENGLISHConnecting the input module signal sourceWhen setting up the projector, you will need to connect the signal source to an input module accordi

Strany 25 - Setting the projection method

ENGLISHConnecting the signal source to the input module for analogue RGB signalsIf using the input module for analogue RGB signals in order to connect

Strany 26 - Adjusting the lens

32ENGLISHThe table below lists the different types of analogue RGB signals that can be input.If a signal which differs greatly from any of the types l

Strany 27

33ENGLISHConnecting the signal source to the input module for video signals1.Connecting a video signal source• Switching between LINE input and Y/C in

Strany 28 - Installing the input module

34ENGLISHConnecting the signal source to the input module for video signals2.Connecting a component signal source• For details of composite and compo

Strany 29 - Installing the input modules

35ENGLISHConnecting the signal source to the input module for TMDS signals• This input module is for use with personal computers which are equipped wi

Strany 30 - VGA to BNC

36ENGLISHConnecting the signal source to the input module for serial digital signals• Use an input module which correctly matches the input signal typ

Strany 31 - ET-MD95RGB

37ENGLISHConnecting the signal source to the input module for serial digital signalsSD signalSD signal output(Active through)Serial digital input modu

Strany 32

38ENGLISH2. 1) 480p single link (4:2:0p): 59.94 Hz progressive scan with 720 by 483 active lines at360 Mbps, complying with the SMPTE294M Standard2) 4

Strany 33 - (Purchase an S-VIDEO

39ENGLISHConnecting the signal source to the input module for serial digital signalsHD SD signalSD signal output(Active through)Serial digital input m

Strany 34 - DVD player

Features4By installing input modules (sold separately), the unit can handle various video sources, including: analog RGBsignals, component signals for

Strany 35 - Personal computer

40ENGLISHSelecting the input signal• The following remote control unit buttons and the INPUT button on the projector operating panel can be used toswi

Strany 36 - SERIAL

41ENGLISHSelecting the signal of ET-MD95VM2(sold separately)When using the projector with the optional ET-MD95VM2 Video Input Module, select the appro

Strany 37 - Professional-type

42ENGLISHRegistering input signal dataBecause the projector has no factory pre-set data of input signals, be sure to register input signal data before

Strany 38

43ENGLISHWhen the memory does not allow new signal registration because it is full• When a total of 64 signals has already been registered and the mem

Strany 39 - ET-MD95SD3 (for HD SDI)

44ENGLISHSub-memoryThis equipment has a sub memory function which enables storage of multiple image adjustment data sets, evenwhen the signal is deter

Strany 40 - Selecting the system format

45ENGLISHOn-screen displayInput switching/Signal switchingThis displays the stored signal name for the STATUS screen during signal switching.Stored si

Strany 41 - Setting procedure

46ENGLISHUsing the RGB REALITY modeThe RGB REALITY mode is a mode for converting RGB (primary color) input signals to component signals,performing hig

Strany 42 - Registering input signal data

47ENGLISHAdjusting the picture automaticallyThe automatic adjustment (AUTO SETUP) is a function to automatically adjust the resolution, clock phase, a

Strany 43

48ENGLISH2. Special signal automatic adjustmentAdjustment procedurePress the MENU button. ... The MENU screen will be displayed.Press the LEFT () or R

Strany 44 - Sub-memory

49ENGLISHSignals which cannot be adjusted automatically should be adjusted manually. The following settings can beadjusted manually, and the respectiv

Strany 45 - Sub-memory list

ENGLISH5IMPORTANT SAFETY NOTICEWARNING: THIS APPARATUS MUST BE EARTHED.WARNING: To prevent damage which may result in fire or shock hazard, do not exp

Strany 46 - Using the RGB REALITY mode

50ENGLISHIf a flicker or bleeding of the contour appears on the screen, adjust the clock phase to obtain an optimum picture.Adjustment procedurePress

Strany 47 - Adjustment procedure

51ENGLISHAdjustment procedurePress the MENU button. ... The MENU screen will be displayed.Press the UP ( ) and DOWN ( ) arrow buttons to select POSIT

Strany 48 -

52ENGLISHAdjusting the blankingAdjustment procedurePress the MENU button. ... The MENU screen will be displayed.Press the UP ( ) and DOWN ( ) arrow bu

Strany 49

53ENGLISH• If the black portions of the picture are fractured or tinged with green, adjust the clamp position its optimumstate.Adjustment procedurePre

Strany 50 - Adjusting the clock phase

54ENGLISH• The KEYSTONE adjustment allows you to compensate for pictures’ horizontal trapezoidal distortion. (Keystone adjustment can not carried out

Strany 51

55ENGLISHAdjusting the picture to the desired settingThe following procedures can be used to adjust the picture to the desire appearance.Adjustment pr

Strany 52 - Adjusting the blanking

56ENGLISHAdjusting the white balanceAdjustment procedure (Project a signal to be adjusted)Press the MENU button. ... The MENU screen will be displayed

Strany 53 - Picture mute function

57ENGLISHNOTEAdjusting the picture qualityThe following procedures can be used to adjust the picture quality to the desired setting.Adjustment procedu

Strany 54

58ENGLISH• NR (noise reduction) settings cannot be adjusted for analogue RGB input and TMDS input.• The FILTER adjustment is ineffective for XGA (1 02

Strany 55

59ENGLISHAdjusting the picture sizeAdjustment procedurePress the MENU button. ... The MENU screen will be displayed.Press the UP ( ) and DOWN ( ) arro

Strany 56 - Adjusting the white balance

ENGLISHPrecautions with regards to safety6Read these operating instructions thoroughly and check all necessary safety precautionswhen setting up the p

Strany 57 - Adjusting the picture quality

60ENGLISHScreen examples for different size settings (For PT-D9510E)INPUT PICTUREDefaultThroughH-FitV-FitHV-Fit8:5(640×400)4:3(1152×864)5:4(1280×1024)

Strany 58 - Adjustment Details

61ENGLISHScreen examples for different size settings(For PT-D9610E)INPUT PICTUREDefaultThroughH-FitV-FitHV-Fit8:5(640×400)4:3(1152×864)5:4(1280×1024)S

Strany 59 - Size modes

62ENGLISHPower up functionThe projector is provided with a power up function which allows the performance of the lamp to be utilized to themaximum lev

Strany 60 - The picture is displayed at

63ENGLISHThis equipment has 3 mode types for adjusting to the use environment.Switching procedurePress the MENU button. ... The MENU screen will be di

Strany 61

64ENGLISHWhen receiving 480i with analog component signal YCbCr input, it is possible to switch Cb, Cr input.Switching procedure Press the MENU button

Strany 62 - Power up function

65ENGLISHDisplaying a test pattern17 types of test pattern are built in. These test patterns can be used to check the various adjustment settings.Use

Strany 63 - Contrast switching function

66ENGLISHDisplaying the projector settingsDisplay procedurePress the MENU button. ... The MENU screen will be displayed.Press the UP ( ) and DOWN ( )

Strany 64 - Switching procedure

67ENGLISHAdjusting the edge blendingAdjustment procedurePress the MENU button. ... The MENU screen will be displayed.Press the UP ( ) and DOWN ( ) arr

Strany 65 - Displaying a test pattern

68ENGLISHAdjusting the color matchingThe projector is equipped with color matching adjustment functions to adjust colour balance when using severaluni

Strany 66

69ENGLISHThis projector is provided with an ID number function, so that if multiple projectors are being used together, theprojectors can be controlle

Strany 67 - Adjusting the edge blending

ENGLISH7When using the projectorDo not look into the lens while the projector is being used.• Strong light is emitted from the projector‘s lens. If yo

Strany 68 - Adjusting the color matching

70ENGLISHSetting remote control unit ID numbersWhen an ID number has been assigned for a projector, you then need to assign the same ID number as thep

Strany 69 - Setting ID numbers

71ENGLISHUsing the RS-232C connectorsThe projector is equipped with a D-SUB 9-pin RS-232C input connector and RS-232C output connector whichallow the

Strany 70 - Setting method

72ENGLISHID ListID Code specifiedALL 00h1 01h2 02h3 03h4 04h5 05h6 06

Strany 71 - Using the RS-232C connectors

73ENGLISHRS-232C settingsSetting procedurePress the MENU button. ... The MENU screen will be displayed.Press the UP ( ) and DOWN ( ) arrow buttons to

Strany 72

74ENGLISHList of basic control commandsCODETarget remote control buttons NAME06h RGB0Ah INPUT10Bh INPUT20Ch INPUT30Fh NEXT10h 111h 212h 313h 414h 515h

Strany 73 - RS-232C settings

75ENGLISHSelecting the RS-422 Serial InterfaceRefit the CPU module.Plug the projector into the wall outlet and set the front MAIN POWER switch to ON.

Strany 74

76ENGLISHRefit the CPU module.Plug the projector into the wall outlet and set the front MAIN POWER switch to ON.Check that the LED to the left of the

Strany 75 - LED indicator

77ENGLISHUsing the network moduleThe network module for this unit has a LAN interface, so the unit can be controlled from the web browser of a PC.The

Strany 76 - (continued)

78ENGLISHOperating procedurePress the MENU button. ... The MENU screen will be displayed.Press the UP ( ) and DOWN ( ) arrow buttons to select OPTION

Strany 77 - Using the network module

79ENGLISHItemFunctionDescriptionHOSTNAMEDHCPIP ADDRNET MASKGATEWAYMAC ADDRChange if necessary when using a DHCP server etc.Turn the DHCP item ON when

Strany 78 - Operating procedure

ENGLISH8Precautions on handlingCAUTIONSetting-upThe following points should always be observed when setting up this projector.A dedicated power supply

Strany 79 - Description

80ENGLISHAccessing from a web browserGo to: 192.168.0.8Start up the PC’s web browser.Input the IP address set on the unit in the URL input field of th

Strany 80 - Projector control window

81ENGLISHTop page TOP-Panasonic projector control window - NetscapeFile Edit View Go Window HelpCopyright (C) 2001 Matsushita Electr

Strany 81

82ENGLISHNetwork setting pageSelect ON to activateDHCP client functionInput IP address whennot using DHCP serverInput port number.Normally, this is us

Strany 82 - Projector control page

83ENGLISHStatus display pageDisplays input slot statusDisplays projectorinternal temperatureDisplays projectorexhaust temperatureDisplays lampillumina

Strany 83 - Status display page

84ENGLISHE-mail setting page• This enables automatic sending of mail to up to two mail addresses.When using the e-mailfunction, select Enable.Input th

Strany 84 - E-mail setting page

85ENGLISHE-mail setting page (continue)When using two e-mailaddresses, input the e-mailaddress to send mail to.After all input is finished, pressthe S

Strany 85

86ENGLISHFirmware update page(Firmware updating should only be done by a person with specialized knowledge.)• When rewriting is finished, this message

Strany 86 - Firmware update page

87ENGLISH• If too much dust accumulates on the air filter, the temperature inside the projector will rise and may cause the power to turn off. Clean t

Strany 87 - Cleaning the air filter

88ENGLISHNotes on handling the lamp unit• The lamp unit is sold separately and consult a Panasonic authorized dealer or service center. Part No. : ET

Strany 88 - Replacing the lamp unit

89ENGLISHBefore asking for service, check the following points.Power does not turn on.No picture appears.Color is misaligned when special

Strany 89

ENGLISH9Notes on useIn order to get the best picture quality• If outside light or light from indoor lamps is shining onto the screen, the images proje

Strany 90 - Specifications

90ENGLISHSpecificationsPT-D9510EPT-D9610E(PT-D9510E)(PT-D9610E)PT-D9510EPT-D9610E 200 V – 240 V AC (single-phase, 3-wire), 14 A (Max.)2.2 kWApprox. 13

Strany 91 - ✕ 2 For wired remote

91ENGLISHAccessories• Remote control unit ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 1• AA-size batteries ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・

Strany 92 - Sold separately

92ENGLISHSold separatelySelect from the range available in accordance with the setting-up location and system requirements.**11 Refer to the ET-D95LE9

Strany 93 - Dimensions

93ENGLISHUNIT : mm (inch)Dimensions960(37.8")428(16.8")680(26.8")753(29.6")604(23.8")1051(41.4")712(28")169(6.7&quo

Strany 94

94ENGLISH

Komentáře k této Příručce

Žádné komentáře