Strany 1 - WJ-MP204

Before attempting to connect or operate this product,please read these instructions carefully and save this manual for future use.Model No. WJ-MP204Da

Strany 2 - ENGLISH VERSION

10Address setting varies from one communication mode to another.The setting should be made by qualified service personnel or system installers. Panas

Strany 3 - CONTENTS

11The Setup menu consists of two main menus: one for communication setup for connection to cameras and the system con-troller WV-CU360, and the other

Strany 4 - FEATURES

12WJ-MP204 SETUP MENU X.XX COMMUNICATION SYSTEM Displaying the Setup Menu forPanasonic Security Data Mode1. Check that the cameras and peripheral

Strany 5 - COMMUNICATION MODE

13 COMMUNICATION UNIT ADDRESS 1 BAUD RATE 9600 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF(6) Wait Time Settin

Strany 6 - ■ Front View

14OFF by pressing button 3 (–) or button 4 (+).The initial factory setting is ON.• Terminal Alarm Setting1. Display the SYSTEM menu.2. Move the cursor

Strany 7 - ■ Rear View

15(2) Comp/VD2/Data Setting• Camera Input Setting1. Display the SYSTEM menu.2. Move the cursor to CAMERA IN by pressing button 1(C) or button 2 (D), p

Strany 8 - SETUP PROCEDURE

16WJ-MP204 SETUP MENU X.XX COMMUNICATION SYSTEM Displaying the Setup Menu ofCamera Communication Mode1. Check that the cameras and peripherals ar

Strany 9 - DIP SWITCH SETTING

17(4) Parity Check Setting1. Display the COMMUNICATION menu.2. Move the cursor to PARITY CHECK by pressing button1 (C) or button 2 (D), then select th

Strany 10 - SETTING ADDRESSES

18 System Setup for CameraCommunication Mode1. Display the Setup menu.2. Move the cursor to SYSTEM by pressing button 1 (C)or button 2 (D), then pres

Strany 11 - (see page 16 - 19)

19ON: Multiplex sync signals (VD2) are generated by syn-chronizing with the signals sent to the VS/VD INconnector. If there is no input signal, the in

Strany 12 - ■ Communication Setup of

2ENGLISH VERSIONThe serial number of this product may be found on the bot-tom of the unit.You should note the serial number of this unit in the spacep

Strany 13 - Security Data Mode

20Joint metalRemove 2 screws from the rear beforehand.Rack mountingbracket (small)Rack mountingbracket (small) Mount screw Binding head (M3x8)Mount sc

Strany 14 - (1) Alarm Mode Setting

21 BASIC SYSTEM CONNECTION (Panasonic Security Data Mode)The Data Multiplex Unit WJ-MP204 may be connected to cameras, video monitors, and system con

Strany 15 - (4) Camera Config

22● Connecting Two or More Data Multiplex Units to System Controller WV-CU360(Panasonic Secuarity Data Mode)SD RDIN INCAMERA RS485ABABGVS/VDSPOT DATAA

Strany 16 - ■ Communication Setup for

23● Connecting Two or More Data Multiplex Units to Matrix Switcher WJ-SX350 (CameraCommunication Mode)TRIN INCAMERA RS485ABABGVS/VDSPOT DATAALARM / RE

Strany 17

24Pin #123456 (1CH)For AlarmInputAlarm OutputAlarm Recover InputAlarm Reset OutputSpot SW InputSpot SW OutputAlarm Input 1 Alarm Output 1(Camera Site

Strany 18 - Communication Mode

2512340/5VO.C4321ON OFFSW702SW704FixedOnly displays the Setup menu to SPOT OUT.Displays the Setup menu to CAMERA OUT (1 - 4) and SPOT OUT.ONSW7021 OFF

Strany 19 - (5) Terminal

26 Connection to WV-CU360● Basic ConnectionConnect the DATA port on the Data Multiplex Unit to one of the DATA port on the System Controller with the

Strany 20 - INSTALLATION

27 Controlling the CameraFunctions with the DataMultiplex Unit WJ-MP204Before starting operation, loosen the screw on the frontcover with a screwdriv

Strany 21 - SIGNAL GND

28ALARM CONTROL FUNCTIONSALARM 001 Alarm InputThe Data Multiplex Unit processes the following alarms.(As to setting, see page 14, 18 and 19.)• Camera

Strany 22 - Video signal

29SPECIFICATIONSSTANDARD ACCESSORYPower Source : 220 - 240 V AC 50 HzPower Consumption : 7 WCamera Input : 1 V[p-p]/75 Ω x 4Spot Input : 1 V[p-p]/75 Ω

Strany 24 - CN 702 ALM OUT

Function30CameraSelectionAlarm ResetAlarm SuspendWJ-MP2044321RESETALARMSETSUSPENDALARMWV-CU360Alarm SuspendResetSETSUSPENDALARMAPPENDIX Operation of

Strany 25 - ■ RS485 Terminal

N1299-1030 YWV8QA5360BN Printed in JapanN 19 Gedruckt in JapanImprimé au JaponImpreso en Japón2000 © Matsushita Communication Industrial Co., Ltd. Al

Strany 26 - Controller end

4PREFACEFEATURESThe WJ-MP204 Data Multiplex Unit enables you to remotecontrol multiple surveillance cameras, check alarm set-tings, operate the camera

Strany 27 - OPERATING PROCEDURES

5PRECAUTIONS• Refer all work related to the installation of thisproduct to qualified service personnel or systeminstallers.• Do not block the ventilat

Strany 28 - ALARM CONTROL FUNCTIONS

6MAJOR OPERATING CONTOROLS AND THEIR FUNCTIONSq Power Switch (POWER ON/OFF)Press once to turn on the Data Multiplex Unit. The switch remains down (;)

Strany 29 - ALL RESET

7 Rear Viewo Camera Input Connectors 1-4 (CAMERA IN 1, 2, 3, 4)These connectors accept the composite video signalfrom the camera.!0 Camera Output Con

Strany 30 - APPENDIX

8Follow the procedures below for setup.1. Press the Power Switch back to the OFF position.Check that the Power Switch LED is off.SETUP PROCEDURE2. Set

Strany 31 - Impreso en Japón

9Before connecting the Data Multiplex Unit, check how theDIP switches are set on the rear panel in cases where thesystem setup must be changed. Setti