3. PC COM. (PC Communication)
This table is used to set the Communication Parameters
between the Personal Computer and the Matrix
Switcher.
Select PC COM. on the SYSTEM menu by moving the
Joystick Controller, then press the CAM (SET) button to
display the PC COM. menu as shown below.
1. Move the cursor to the BAUD RATE parameter by
moving the Joystick Controller. Then set the Baud
Rate to 2400, 4800, 9600 or 19200 by pressing the
+1CAM INC or –1CAM DEC button.
2. Move the cursor to the DATA BIT parameter by
moving the Joystick Controller. Then set the Data
Bit to 7 or 8 by pressing the +1CAM INC or –1CAM
DEC button.
3. Move the cursor to the PARITY CHECK parameter
by moving the Joystick Controller. Then set Parity
Check to ODD, EVEN or NONE by pressing the
+1CAM INC or –1CAM DEC button.
4. Move the cursor to the STOP BIT parameter by
moving the Joystick Controller. Then set the Stop Bit
to 1 or 2 by pressing the +1CAM INC or –1CAM
DEC button.
5. Move the cursor to the XON/OFF parameter by
moving the Joystick Controller. Then set the Mode
to ON or OFF by pressing the +1CAM INC or
–1CAM DEC button.
6. Move the cursor to the WAIT TIME parameter by
moving the Joystick Controller. Then set the Wait
Time to 100, 200, 400, 1000 or OFF by pressing the
+1CAM INC or –1CAM DEC button.
7. After completing the table, press the MON (ESC)
button to escape from the programming mode and
return to the previous SYSTEM menu.
4. CAM PORT SELECT (Camera Port
Select)
This table is used to select either RS485 port 1 or 2 for
the cameras.
Up to sixteen (16) cameras can be assingned to each
port.
Move the cursor to CAM PORT SELECT on the SYSTEM
menu by moving the Joystick Controller, then press the
CAM (SET) button to display the CAM PORT SELECT
menu as shown below.
1. Move the cursor to a Camera Number parameter by
moving the Joystick Controller. Then set the
Camera Port to 1, 2 or – by pressing the +1CAM
INC or –1CAM DEC button.
1: Communicates through port 1
2: Communicates through port 2
–: No communication
Note: Select 1 or 2, if the associated camera site
units are connected. If not, always set the para-
meter to “–”.
2. Repeat the above procedure for the other Camera
Numbers until the table is completed.
3. After completing the table, press the MON (ESC)
button to escape from the programming mode and
return to the previous SYSTEM menu.