Possible
to use on
R22 pipings
R22 RENEWAL
Kit Silver Plated KIT-XE7-QKE KIT-XE9-QKE KIT-XE12-QKE —
Kit Silver Plated / with Smartphone Control KIT-XE7-QKE-WIFI KIT-XE9-QKE-WIFI KIT-XE12-QKE-WIFI —
Kit White KIT-E7-QKE KIT-E9-QKE KIT-E12-QKE KIT-E15-QKE
Kit White / with Smartphone Control KIT-E7-QKE-WIFI KIT-E9-QKE-WIFI KIT-E12-QKE-WIFI KIT-E15-QKE-WIFI
Indoor Silver plated CS-XE7QKEW CS-XE9QKEW CS-XE12QKEW —
Indoor White CS-E7QKEW CS-E9QKEW CS-E12QKEW CS-E15QKEW
Outdoor CU-E7QKE CU-E9QKE CU-E12QKE CU-E15QKE
Cooling capacity Nominal (Min - Max) kW 2,05 (0,75 - 2,40) 2,50 (0,85 - 3,00) 3,50 (0,85 - 4,00) 4,20 (0,85 - 5,00)
Nominal (Min - Max) kCal/h 1.760 (650 - 2.060) 2.150 (730 - 2.580) 3.010 (730 - 3.440) 3.610 (730 - 4.300)
SEER Nominal Energy Saving
6,90 i 6,90 i 7,60 i 6,60 i
Pdesign (cooling) kW 2,1 2,5 3,5 4,2
Power input cooling Nominal (Min - Max) kW 0,460 (0,240 - 0,565) 0,525 (0,245 - 0,715) 0,835 (0,250 - 1,050) 1,240 (0,260 - 1,540)
Annual electricity consumption (cooling)
1)
kWh/a 107 127 161 223
Heating capacity Nominal (Min - Max) kW 2,80 (0,70 - 4,00) 3,40 (0,80 - 5,00) 4,00 (0,80 - 6,00) 5,30 (0,80 - 6,80)
Heating capacity at -7°C Nominal kW 2,38 2,95 3,45 4,11
SCOP Nominal Energy Saving
4,40 h 4,70 i 4,80 i 4,00 h
Pdesign at -10°C kW 2,1 2,7 3,2 3,6
Power input heating Nominal (Min - Max) kW 0,625 (0,180 - 1,000) 0,720 (0,190 - 1,270) 0,840 (0,190 - 1,600) 1,420 (0,190 - 1,920)
Annual electricity consumption (heating)
1)
kWh/a 668 804 933 1.260
Indoor Unit
Power source V 230 230 230 230
Recommended fuse A 16 16 16 16
Recommended power cable section mm² 1,5 1,5 1,5 1,5
Connection indoor / outdoor mm² 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5
Current (Nominal) Cooling / Heating A 2,20 / 2,80 2.35 / 3,20 3,80 / 3,90 5,50 / 6,30
Maximum current A 4,40 5,6 7,40 8,5
Air volume Cooling / Heating m³/h 726 / 738 768 / 774 804 / 822 852 / 876
Moisture removal volume l/h 1,3 1,5 2 2,4
Sound pressure level
2)
Cooling (Hi / Lo / Q-Lo) dB(A) 37 / 24 / 20 39 / 25 / 20 42 / 28 / 20 43 / 31 / 25
Heating (Hi / Lo / Q-Lo) dB(A) 38 / 25 / 20 40 / 27 / 20 42 / 33 / 20 43 / 35 / 29
Sound power level Cooling / Heating (Hi) dB 53 / 54 55 / 56 58 / 58 59 / 59
Dimensions H x W x D mm 295 x 870 x 255 295 x 870 x 255 295 x 870 x 255 295 x 870 x 255
Net weight kg 10 10 10 10
Air purifier filter Nanoe-G Nanoe-G Nanoe-G Nanoe-G
Outdoor Unit
Air volume Cooling / Heating m³/h 2.034 / 2.034 1.788 / 1.788 2.106 / 2.160 1.998 / 1.998
Sound pressure level
2)
Cooling / Heating (Hi) dB(A) 45 / 46 46 / 47 48 / 50 49 / 51
Sound power level Cooling / Heating (Hi) dB 60 / 61 61 / 62 63 / 65 64 / 66
Dimensions
3)
H x W x D mm 542 x 780 x 289 542 x 780 x 289 619 x 824 x 299 619 x 824 x 299
Net weight kg 31 33 35 33
Piping connections Liquid pipe / Gas pipe inch (mm) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 1/2 (12,70)
Refrigerant loading R410A (GWP value) kg 0,85 1,02 1,15 1,02
Elevation difference (in/out)
4)
Maxm15151515
Piping length Min / Max m 3 / 15 3 / 15 3 / 15 3 / 15
Precharge length Max m 7,5 7,5 7,5 7,5
Additional charge g/m 20 20 20 20
Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43
Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24
Etherea with enhanced Econavi sensor and new Nanoe-G air-purifying system: outstanding
efficiency, comfort and healthy air combined with state-of-the-art design.
Econavi features an in-built human activity sensor and a new sunlight detection technology to adjust output
thereby giving you the best comfort at anytime whilst saving energy. Econavi not only optimizes air flow
orientation and volume according to human presence, it also reduces cooling power automatically by no/less
sunshine. With Econavi, energy savings of up to 38% are possible, whilst increasing your comfort.
Furthermore, the Nanoe-G revolutionary air-purifying system utilises nano technology fine particles to remove
and deactivate 99% of both airborne and adhesive micro-organisms like bacteria, viruses and mould.
WALL MOUNTED ETHEREA
INVERTER+
SILVER PLATED / WHITE
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-XE12-QKE and KIT-E12-QKE. MILD DRY: Maintains a Relative Humidity up to 10% higher than cooling operation. Ideal when sleeping with the air conditioner on. SUPER QUIET: For XE7, XE9, XE12, E7, E9 and XE12.Awarded with the
prestigious IF Design
Award 2013
Energy
saving
SUPER QUIET
Silent air
20 dB
Easy
control
by BMS
CONNECTIVITY
5 year
compressor
warranty
Up to 38%
energy savings
(cooling)
Air purifier
99%
removal
bacteria · virus · mold
Perfect
humidity
control
MILD DRY
Improved
comfort
AUTOCOMFORT
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with QKE units.
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 metre in front of the main body and 0,8 m below the unit. The sound pressure is measured in
accordance with Eurovent 6/C/006-97 specification. Q-Lo: Quiet mode. Lo: The lowest fan speed. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
4,80 A++
SCOP
SEASONAL COEFFICIENT
OF PERFORMANCE
7,60 A++
SEER
SEASONAL ENERGY
EFFICIENCY RATIO
42
Il est indiqué manuel en français, mais hélas a la visualisation et téléchargement il est anglais. Pourriez vous m envoyer le document pour le climatiseur panasonic CU-UE9PKE en Français, à défaut comment et oi le trouver en français.