10. Installation Instruction
10.1 S9NKUA S12NKUA
10.1.1 Select the Best Location
10.1.1.1 Indoor Unit
Do not install the unit in excessive oil fume area
such as kitchen, workshop and etc.
There should not be any heat source or steam
near the unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit
shall be at least 8.2 ft.
10.1.1.2 Outdoor Unit
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a
short circuit of the discharged air.
If piping length is over the [piping length for
additional gas], additional refrigerant should be
added as shown in the table.
Example: For S9NKUA
If the unit is installed at 32.8 ft distance, the quantity of
additional refrigerant should be 1.64 oz .... (32.8 - 24.6)
ft x 0.2 oz/ft = 1.64 oz.
10.1.2 Indoor/Outdoor Unit Installation
Diagram
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - 10. Installation Instruction

19 10. Installation Instruction 10.1 S9NKUA S12NKUA 10.1.1 Select the Best Location 10.1.1.1 Indoor Unit • Do not install the unit in excessive oi

Strany 2 - Install a Sleeve of Piping

20 10.1.3 Indoor Unit 10.1.3.1 How to Fix Installation Plate The mounting wall shall be strong and solid enough to prevent if from the vibration.

Strany 3

21 10.1.3.3 Indoor Unit Installation 10.1.3.4 For the right rear piping 10.1.3.5 For the right bottom piping 10.1.3.6 For the embedded piping

Strany 4

22 10.1.3.7 Connect the Cable to the Indoor Unit 1. The inside and outside connection cable can be connected without removing the front grille. 2

Strany 5

23 10.1.3.8 Wire Stripping and connecting requirement 10.1.3.9 Cutting and flaring the piping 1 Please cut using pipe cutter and then remove the

Strany 6

24 10.1.4 Outdoor Unit 10.1.4.1 Install the Outdoor Unit • After selecting the best location, start installation to Indoor/Outdoor Unit Installation

Strany 7 - with a torque wrench

25 10.1.4.3 Evacuation of the equipment WHEN INSTALLATION AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the fol

Strany 8 - 10.1.4.5 Piping Insulation

26 9. Secure the wire onto the control board with the holder (clamper). 10. After completing wiring connections, reattach the control board cover (