Global Camera Numbering
This function allows operators to select global camera by just input a logical camera number that is unique number
in the whole multiple domains system. The global camera number can be assigned from 1 to 9999999.
● WV-ASC970 Admin Console Setting
If operators would like to use global camera numbering, the system administrator should turn on the global camera
numbering select check box in the WV-ASC970 Admin Console CPU screen first. Then he/she retrieve all camera
databases from each domain.
Andthenhe/sheshouldassigntheglobalcameranumbertoeachdomain'scameraontheWV-ASC970Admin
Console screen manually.
Note:
• TheassignedglobalcameranumberingdatabaseisincludedintheWV-ASC970AdminConsoleglobaldata-
base. It is necessary to download not only local database, but also global one.
• Inthemultipledomainssystem,theglobalcameranumberingandthecurrentnumberingcannotbemixedup.It
is necessary to download same global database to each domain.
● Global Camera Numbering Setting Example
Global Logical Camera Number Unit ID Local Logical Camera Number
2043 3 1
2044 2 2
2045 1 3
2046 3 3
● Operation Example
1. Login to System Controller: Enter 500 for ID and enter 500 for password (Global Operator).
2. Select monitor 1: Enter 1 and press MONITOR key.
3. Select a global camera 2043: Enter 2043 and press CAMERA key.
4. ThentheUnit3'scamera1isdisplayedonthemonitor1.
Note:
• OnlyGlobalOperatorcanaccessforeigndomaincameras.
In above example, the local operator in the Unit 3 cannot select camera 2044 and 2045.
• WhenalocaloperatorperformsthecameraNEXT/PREVoperation(or+/-keyoperation),theforeigndomain
cameras are skipped.
• Ifthereisnovideolink,operatorcannotselecttheforeigndomaincameras.
● Global Tour Sequence Over the domains
By using global camera number, the system administrator can configure the Global Tour Sequence over the
domains. Only Global Operator can see all steps on the tour. The local operator can see only local cameras in the
tour.
The global tour sequence over the domains can be assigned from 1 to 9999 and maximum records are 5000.