19
8OperationDetails
8.1.CoolingModeOperation
WhenselectingtheCoolingModeOperation,theunitwilloperateaccordingtothesettingbytheRemoteControlleror
thecontrolpanelontheindoorunitandtheoperationisasthefollowing.
TimeDelaySafetyControl
3min.----Ifthecompressorstops,itwillnotrestartwithin3minutes.(Protectionofcompressor).
7MinutesTimeSaveControl
7min.----Theunitwillautomaticallyoperatein7minuteseveniftheroomtemperatureisnotreached.
(Preventionofraisingthehumidity)
Evaporator
Temperature
()
10
2
Restart
4minutes
Compressorceases
Time
Anti-FreezingControl
Iftemperatureofevaporatorislowerthan2continuously
for4minutes,thecompressorwillceasetopreventthe
evaporatorfromfreezing.Fanspeedsettingwillnotbe
changed.
Whentemperatureofevaporatorreaches10,compressor
willrestart.
DuringCoolingModeOperation,theTimeDelaySafety
Controlisavailable.
IndoorFan
STOP
Slow
Slow
STOPSTOP
SlowSlow
STOP
ON
Compressor
ON
1FanspeedwillbeatHitillthecompressorceases(settemperaturereached).
2FanspeedwillbeatMewhenthecompressorrestarts.
40 30 40 3020 160
1
2
AutomaticFanSpeedMode
DuringCoolingModeOperation,useremotecontrollertoselectAutomaticFanSpeed.
Deodorizationcontrol.
Fanspeedwillbeatthepointbetween"Highspeed"and"Mediumspeed".
CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE