8.4.AutomaticModeOperation
StandardforDeterminingOperationMode
Coolingmode
SoftDrymode
Heatingmode
Coolingmode
SoftDrymode
Heatingmode
IntakeAir
temperature
SettingTemperature(Standard)
23
20
25
22
21
Onehouraftertheabovedetermination,theunitwilloperateaccordingtothetablebelow.
First
determination
Cooling
Dry
Heating
SecondDetermination
Cooling
Dry
Heating
23orabove
25orabove
20orabove
23below
20below
25below
SecondDetermination:
FirstDetermination:
Higher
Standard
Lower
2
0
2
Indoorfanoperatesatsuperlowspeedfor25seconds.
Afterjudgingindoorairtemperature,theoperationisdeterminedandoperationcontinuedatthemodedetermined.
Ifindoortemperatureislessthan16,heatingoperationwillimmediatelyoperate.
Aftertheoperationmodehasbeendetermined,themodedoesnotchange.However,SoftDrymodeoperation
includescoolingmodeoperation.
Ifautomaticmodeoperationisstartedwhiletheunitisoperating,operationwillcontinue.
Ifcurrentoperationisincoolingmode(includingthecoolingmodeoperationwhenisapartofSoftDrymode
operation)itwillbemaintained,andifcurrentoperationisnotcoolingmode,theappropriateoperationmodeis
determinedfor25secondsatsuperslowfanspeed.Thentheselectedmodewillcontinue.
Roomtemperatureadjustment
A)
B)
C)
D)
E)
F)
26
CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE